F38
CONTROL SYSTEM
.
L8, LF (General area) engine models
.
• The PCM energized the cooling fan relay No. 1
and No. 2 (with A/C system) except all of
following condition are met.
ECT: below 100 °
°°
°C [176 °
°°
°F]
A/C: OFF (with A/C system)
End Of Sie
CONTROLLER AREA NETWORK (CAN)
A6E394018881T15
• PCM transmit/received the information in the CAN. For detail information of the CAN, see the MULTIPLEX
COMMUNICATION SYSTEM. (See T5 OUTLINE.)
A6E3940T220
1 Cooling fan motor No. 1
2 Cooling fan motor No. 2
3 Cooling fan relay No. 1
4 Cooling fan relay No. 2
5 Cooling fan relay No. 3
6 Cooling fan relay No. 4
7PCM
8 L3 engine models
9 LF, L8 engine models (Intensely hot area)
1 Cooling fan motor No. 1
2 Cooling fan motor No. 2
3 Cooling fan relay No. 1
4 Cooling fan relay No. 2
5PCM
6 With A/C system
A6E3940T221