5-6-2 : Fine adjustment of fold position
If by test folds any folding misalignment is found after standard folding or non-standard folding is set,
fine adjustment of the fold position should be made according to the following procedure.
[1] In case of “a”
Press the “+/-“ key and move the stopper to the desired
position.
[2] In case of “b”
Press the “+/-“ key and move the stopper to the desired
position.
[3] Press the “TEST” key to perform test folding.
If test folding is satisfactory, proceed to step [6].
If it is not satisfactory, adjust folding misalignment.
When readjustment is required, repeat the above
procedure [1] to [4].
[4] Press the “START/STOP” key to conduct
continuous folding
Using fine adjustment knob
Move the stopper using the stopper fine adjustment knob.
Caution: (In case the stopper fine adjustment knob is moved)
When the Test key is pressed, the machine will continue to fold,
and when the Start/Stop key is pressed, the machine will start to
fold after the stopper is returned to the previous position