Operation
Figure 30
4. PUSH and HOLD in the winch/reeving lever to retract the
cable and slowly raise the container to dump position.
Release the winch/reeving lever when the container
reaches the dump position.
5. When the container has been emptied, PULL the winch/
reeving lever to extend the cable and slowly lower
the container. Raise the winch/reeving lever when the
container is lowered to ground level.
6. Unhook the cable from the container, then carefully retract
and latch the hook to the cable ring provided (Figure 31).
Retract the cable further, just enough to “snug” it securely
to the ring.
1
Figure 31
7. Release the container latch on each side of the container
(See Section 4.2 Container Lock.).