Problem Possible Cause Remedy
No power to power points Caravan not plugged into mains power.
• Faulty power lead
• RDC Device tripped
• Plug into mains power.
• Test/replace lead.
• Reset RCD
RDC Keeps Tripping • Faulty Appliance
• Short in system
• Check appliance.
Have electrician check caravan electri-
cal system
Problem Possible Cause Remedy
No 12 Volt Power Main isolator Turned Off.
Batteries Flat
Main mega fuse tripped
Turn on main isolator.
Charge Batteries
Reset Mega fuse
Batteries wont charge Batteries below minimum voltage
Batteries failed.
Charger not turned on.
Charger not plugged in
No mains power.
Faulty Charger
Switch charger to “Supply Mode” and
charge until holding 6 volts then switch
to AGM charge mode.
Replace batteries.
Turn on charger.
Plug in charger and turn on.
Connect mains power.
Replace charger
Solar power not charging Tripped circuit breaker
Faulty DC to DC unit
Night-time
Parked in shade
Reset breaker.
Replace or repair DC to DC unit
Wait until daytime.
Park in sunshine
Batteries not charging from
car
No power from car
DC to DC trigger wire not activated
Tripped breaker
Check car power output.
Connect trigger wire through pin 12 to
vehicle accessory power.
Reset breaker
Trailer lights not working Trailer plug pins not separated.
Car not providing power.
Bad connection in plug
Separate pins using the split in each pin
to ensure good contact with car plug.
Check output from car trailer plug.
Check wire connections in plug
Lights or plugs not working Circuit not switched on at panel.
Batteries at
Circuit breaker tripped
Switch on at control panel.
Charge batteries
Reset breaker
No Power to portable fridge Tripped circuit breaker
Faulty Socket
Reset circuit breaker.
Test socket with test light or multimeter
Inverter not powering Mega fuse tripped.
Battery voltage too low
Reset mega fuse.
Charge batteries
Circuit breaker tripping during
use
Appliance load too high
Faulty breaker
Check appliance for fault.
Replace breaker
Trouble Shooting
240 Volt Trouble Shooting
12 Volt Trouble Shooting