48
Trouble Shoong
240 Volt Trouble Shoong
Problem
Possible Cause
Remedy
No power to power points
Caravan not plugged into mains power.
Faulty power lead
RDC Device tripped
Plug into mains power.
Test/replace lead.
Reset RCD
RDC Keeps Tripping
Faulty Appliance
Short in system
Check appliance.
Have electrician check caravan
electrical system
12 Volt Trouble Shoong
Problem
Possible Cause
Remedy
No 12 Volt Power
Main isolator Turned Off.
Baeries Flat
Main mega fuse tripped
Turn on main isolator.
Charge Baeries
Reset Mega fuse
Baeries wont charge
Baeries below minimum voltage
Baeries failed.
Charger not turned on.
Charger not plugged in
No mains power.
Faulty Charger
Switch charger to “Supply Mode” and charge
unl holding 6 volts then switch to AGM
charge mode.
Replace baeries.
Turn on charger.
Plug in charger and turn on.
Connect mains power.
Replace charger
Solar power not charging
Tripped circuit breaker
Faulty DC to DC unit
Night-me
Parked in shade
Reset breaker.
Replace or repair DC to DC unit
Wait unl dayme.
Park in sunshine
Baeries not charging from
car
No power from car
DC to DC trigger wire not acvated
Tripped breaker
Check car power output.
Connect trigger wire through pin 12 to vehicle
accessory power.
Reset breaker
Trailer lights not working
Trailer plug pins not separated.
Car not providing power.
Bad connecon in plug
Separate pins using the split in each pin to
ensure good contact with car plug.
Check output from car trailer plug.
Check wire connecons in plug
Lights or plugs not working
Circuit not switched on at panel.
Baeries flat
Circuit breaker tripped
Switch on at control panel.
Charge baeries
Reset breaker
No Power to portable fridge
Tripped circuit breaker
Faulty Socket
Reset circuit breaker.
Test socket with test light or mulmeter
Inverter not powering
Mega fuse tripped.
Baery voltage too low
Reset mega fuse.
Charge baeries
Circuit breaker tripping
during use
Appliance load too high
Faulty breaker
Check appliance for fault.
Replace breaker

Table of Contents