Page 2-8
May 2005 1532ES / 1932ES Operators Manual
PRESTART INSPECTION
Before use each day or at the beginning of each shift, the machine shall be given a visual
inspection and functional test. Repairs (if any) must be made prior to operating the machine
as it is critical to ensure safe operation of the machine.
Visually inspect all machine components; for loose or missing parts, hydraulic
fluid leaks, loose or damaged wires. Check for structural or weld cracks.
Check fluid levels with the platform fully lowered.
Check the wheel lug nuts for tightness (Refer to Machine Specifications).
Check that all warning and instructional labels are legible and secure.
Check the platform guard rail system. Insure platform entry properly closes and
secures.
Ensure that emergency stop buttons on the base control panel and the platform
controls are disengaged. Reset by turning clockwise.
Ensure that the battery disconnect switch is in the ON position.
MACHINE START UP
1. Ensure the battery disconnect switch, located on Base Control Box, is in the ON
position.
2. Place the base/platform select switch to the desired position.
3. The machine can now be operated from the selected position.
NOTE: If the machine fails to operate, inspect the motor controller inside the motor
compartment. A green LED located on the controller should be illuminated.
If the LED is not illuminated, refer to the troubleshooting section.