EasyManua.ls Logo

Mec 1932ES - Lubrication Chart

Default Icon
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 3-11
1532ES / 1932ES Operators Manual May 2005
SPECIFICATION
Anti-Wear 150 SSU (ISO 32/mil spec 0-5606)
Fill To The Top Of The Sight Gauge With Plat-
form In The Stowed Position.
Filter Element
Lithium N.L.G. #2 EP
Purge Old Grease
FREQUENCY OF
LUBRICATION
Check Daily.
Analyze Every
Six (6) Months Or
500 Hours.
Change Yearly Or
Every 1,000 Hours,
Whichever Occurs
First.
Change Every Six
Months Or 500
Hours, Whichever
Occurs First For
Normal Usage.
Change Every
Three Months Or
300 Hours, Which-
ever Occurs First
For Severe Usage.
Weekly or Every 25
Hours,
Whichever Occurs
First
LUBRICATION CHART
ITEM
Hydraulic
Reservoir
Hydraulic
Filter
Wheel
Motor
Mount
NO.
1
2
3

Other manuals for Mec 1932ES