Page 2-17
1532ES / 1932ES Operator’s Manual May 2005
EMERGENCY LOWERING
The Emergency Down System is used to lower the platform in case of power or valve
failure. To lower the platform, perform the following steps:
1. Pull and turn knurled knob on lift cylinder counterclockwise to lock the valve in open
position.
2. Pull manual activator (override valve) on main manifold to lower platform to
desired height.
3. To return to normal operation, turn knurled knob on lift cylinder clockwise. Valve will
automatically lock.
8599
Cylinder
Valve
Manual Activator
8599