Page 43 85
-
J - Operator’s Manual - 95803
January 2024Section 8 - Maintenance
Lubrication
Operator may perform routine maintenance only. Lubrication listed as Scheduled Maintenance must
be performed by a qualied service technician.
ART_5797
ILLUSTRATION No.
ADD OIL HERE
DRAIN OIL
HERE
OIL LEVEL
1
3
2
HYDRAULIC FLUID
SIGHT GAUGE
Controls Module
Components Removed For Clarity
Item Specication Frequency
1 Hubs
SAE 90 Multipurpose Hypoid Gear Oil
API Service Classication GL5
Scheduled Maintenance
Check every three months or 150 hours,
whichever occurs rst.
Change yearly or every 600 hours, whichever
occurs rst.
2
Hydraulic
Reservoir
Fluid Type
Chevron 1000THF Chevron
Rando Premium MV
Temperature Range
>30° F (0° C)
< 30° F (0° C)
Routine Maintenance
Check level daily
Scheduled Maintenance
Change yearly or every 600 hours, whichever
occurs rst
Do not substitute other uids as pump damage may result.
Fill to the middle of the sight gauge with platform in the
stowed position and stabilizers retracted.
3
Hydraulic
Filter
Filter Element
(Located inside Hydraulic Reservoir)
Scheduled Maintenance
Normal Conditions
Change every six months or 300 hours,
whichever occurs rst
Severe Conditions -- very dusty, exceptionally
hot or exceptionally cold conditions
Change every three months or 150 hours,
whichever occurs rst