No. Display text Note / possible cause Measures / remedial action
106
Wash time increase
insufficient
Tank heating defective
Boiler heating defective
Supply valve defective
If the error message reoccurs,
call a service engineer
107
No signal from tank
level sensor
Plug connection of the wiring
Cable breakage in wiring
Pressure sensor defective
Not possible to continue work-
ing
Call a service technician!
108
Tank temperature
sensor shortcut
Short-circuit in the wiring
Moisture in the connector
Temperature sensor defective
Not possible to continue work-
ing
Call a service technician!
109
Temp. sensor wash
tanks interrupted
Connector incorrectly connected;
crimp connection insufficient
Cable breakage in wiring
Not possible to continue work-
ing
Call a service technician!
110
Temperature moni-
toring drain pump
Notify service tech-
nician!
The discharge pump is possibly
blocked
Transport of waste water no longer
possible
Operation not possible until the
blockage is removed
Level detection defective
Shut off local water supply
Switch off the building-side
fuses
Call a service technician!
111
Water loss in wash
tank
Ventilating valve clogged
Leakage in level control system
If the error message reoccurs,
call a service engineer!
112
Forced drainage
due to permanently
filled wash tank
The tank had not been drained for
a long period of time
Change the water or drain the
machine at least once a day
114
Fine/coarse sieve
missing
Fine/coarse sieve
not present
inserted incorrectly
Cable breakage
Sensor defective
Magnet missing
Correctly insert fine/coarse
sieve
If the error message reoccurs,
call a service engineer
115
Drain pump active
after triggering of
the safety level
Tank overfilled
Supply valve does not close
Safety level exceeded
Possible to continue working

Other manuals for Meiko M-iClean UM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Meiko M-iClean UM and is the answer not in the manual?

Meiko M-iClean UM Specifications

General IconGeneral
BrandMeiko
ModelM-iClean UM
CategoryDishwasher
LanguageEnglish

Related product manuals