ENGLISH
75
Problem Cause Solution
The brewing unit
can no longer be
reinserted after
removal.
The brewing unit is not
properly locked.
Check whether the handle
for locking the brewing unit is
correctly engaged.
The actuator is not in the
proper position.
Switch the appliance off and
on again, an then press the
buttons for one- and two-
cup dispensing
simultaneously for longer
than 2 seconds. The actuator
moves into position. Then
reinsert the brewing unit and
make sure it is correctly locked
into place.
The buttons for
one- and two-cup
dispensing
ash alternately with
the ON/OFF button
.
The brewing unit is
missing or is not properly
inserted.
Insert the brewing unit
properly.
The brewing chamber is
overlled.
Switch the appliance off and
on again via the power switch
(repeat if necessary), until
standby mode is displayed.
Continuous ashing
of all buttons
System error Switch the appliance off and
on again via the power switch,
if this does not work, send
the appliance to Customer
Service.
Please contact the Melitta
®
hotline, if the above mentioned solutions do not help to
solve the problem: +49 571/ 86 1900.