4.12 NATURAL GAS TO LPG CONVERSION
WARNING
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s
instructions and all applicable codes and requirements of the authority having jurisdiction. If the
information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide
may result causing property damage, personal injury or loss of life. The qualified service agency is
responsible for the proper installation of this kit. The installation is not proper and complete until the
operation of the converted appliance is checked as specifie d in the owner instructions supplied with the kit.
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts
specifically approved with this appliance may result in property damage or personal injury.
General Conversion Information
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts
specifically approved with this appliance may result in property damage or personal injury.
Caution: The electrical supply to the fireplace must be turned off prior to performing the conversion. The
gas supply must be shut off prior to disconnecting the electrical power.
Orifice sizes requirement
A Natural Gas to LPG conversion kit #HA-48-00025 must be ordered and installed to convert the M27 Fireplace to burn LPG.
LP Conversion Kit # HA-48-00025 contains the following parts: One manual Pressure Regulator, One LP Pilot Orifice Thimble,
One Cap Orifice drill #56 (for rear burner) and One Cap Orifice drill #59 (for front burner). Specifically, identify the Rear and
Front Burner Cap Orifices. Use proper sized drill bits’ shaft ends to verify orifice size.
Procedure to Convert This Fireplace to Burn LPG
Refer to these diagrams during the conversion processes: