EasyManua.ls Logo

Mercury 2.8 EI 200 - Multiple Electronic Control Engine Battery Precautions

Mercury 2.8 EI 200
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MAINTENANCE
SECTION 5
Page 79CMD-4081877 / 90-865861040 MARCH 2004
INSPECTION
NOTE: Remove deposits from surface of anode before trying to determine amount of
erosion.
1. Replace anode assembly when deteriorated 50%.
Length When New - 19 mm (3/4 in.)
Diameter When New - 16 mm (5/8 in.)
2. Discard sealing washer.
c
d
e
b
a
71368
a-Anode Plug
b-Sacrificial Anode
c-Length
d-Diameter
e-Sealing Washer
REPAIR
NOTE: Sacrificial anodes are available as an assembly. Replace both the plug and anode,
if so desired.
1. Unscrew sacrificial anode from anode plug by holding plug hex head and turning anode.
71367
a
b
a-Plug
b-Anode
2. Clean interior threads of anode plug.
3. Apply sealant to threads of new sacrificial anode and install into anode plug. Tighten
securely.
71367
a
b
A
a-Plug
b-Anode
Description
Where Used Part Number
A Loctite 567 PST Pipe Sealant Threads of anode plug 92-809822

Table of Contents