Additional requirements for the servo drives concerning the UL approval Page 27
5.3 Pin assignment Encoder [X2B]
At the 15-pole D-Sub connection [X2B], motors with encoder can be fed back. The possible incremental
encoders for the encoder connection are divided into several groups. The universal encoder input [X2B]
can be used for one of the described encoder types.
Analog incremental encoder
Incremental encoder with serial communication interface (for example EnDat, HIPERFACE
®
)
Digital incremental encoder
Output of the analog incremental
encoder interface at the motor
D-SUB connector
at X2B
Shield connector
SK 14
Cable shield
(optional)
Connector housing
2
3
4
5
9
10
11
1
12
6
7
8
13
14
15
1
9
8
15
COS_Z0
#COS_Z0
#SIN_Z1
#SIN_Z0
SIN_Z1
#COS_Z1
COS_Z1
#R
SIN_Z0
R
GND
US
U_SENS-
U_SENS+
TEMP+
TEMP-
Male
Figure 6: Pin assignment: Analog incremental encoder [X2B]
In case of wrong activated voltage supply, the encoder can be destroyed! Make sure the
correct supply voltage is activated, before connected to [X2B]!
Therefore, start the parameterization software Metronix ServoCommander
®
and select
Parameters/Device parameters/Angle encoder settings.
Figure 7: Metronix ServoCommander
®
: Angle encoder settings [X2B]
Mounting Instructions „Servo drives ARS 2100 SE“ Version 5.0

Other manuals for Metronix ARS 2100 SE Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Metronix ARS 2100 SE Series and is the answer not in the manual?

Metronix ARS 2100 SE Series Specifications

General IconGeneral
BrandMetronix
ModelARS 2100 SE Series
CategoryServo Drives
LanguageEnglish

Related product manuals