EasyManua.ls Logo

MG Windsor EV - Page 223

MG Windsor EV
249 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1
Month
6
Months
1
Year
2
Years
3
Years
4
Years
5
Years
6
Years
7
Years
8
Years
9
Years
10
Years
OPERATION / PROCESSES FOR
PERIODIC SERVICE SCHEDULE
Replacement
Frequency: Km /
Year whichever
is earlier
1000
5000
15000
30000
45000
60000
75000
90000
105000
120000
135000
150000
Check the level and concentration
of coolant, and add to the standard
level as necessary.
30K KM/
2 Years*
I I I R I R I R I R I R
Check the status of A/C system
pipeline such as the compressor,
the cooling pipeline and the
condenser, and clean relevant
surfaces as necessary.
Inspection only I I I I I I I I I I I I
Check the status of brake vacuum
booster and hose.
Inspection only I I I I I I I I I I I I
Check the drive motor mounting
bracket.
Inspection only I I I I I I I I I I I I
Vehicle Bottom
Check the appearance of high-
voltage connector and if it is fitted
properly; check the surface of
high-voltage connector for damage
and if it is fitted in place.
Inspection only I I I I I I I I I I I I
Check reducer oil level and add to
the standard level as necessary.
First 5K then
every 30 K KM/
2 Years
I R I R I R I R I R I R
Check the high-voltage harness
for mutual interference, wear or
damage.
Inspection only I I I I I I I I I I I I
Check the appearance of vent valve
for damage, and check the marking
for fitting to see if it is moved.
Inspection only I I I I I I I I I I I I
Check the status of manual service
switch to ensure reliable mounting
and clean up the dust on the
surface.
Inspection only I I I I I I I I I I I I
Check the mounting position of the
cooling water pipe clip to ensure
reliable sealing.
Inspection only I I I I I I I I I I I I
Periodic Maintenance - Service Schedule - Windsor
PERIODIC MAINTENANCE
Symbol Abbreviation: R - Replace • I - Inspect- Top up if require-Adjust-Clean-Refill. Check the coolant level and top up as required, replace
if it is contaminated/discoloured or there is sludge formation.
** Tightening of underbody fasteners, door adjustments and functional checks of all the systems during every service is mandatory - Check
5
R e p a i r & M a i n t e n a n c e
5-45

Table of Contents