Aqua Tempo Super II
201709 93
Part
4 - Diagnosis and Troubleshooting
4.22 H6 Troubleshooting
Digital display output 4.22.1
Description 4.22.2
DC bus voltage protection.
Only occurred in standby status.
Error code is displayed on main PCB and user interface.
Possible causes 4.22.3
Abnormal power supply voltage
Loosened wiring within electric control box.
High voltage circuit error.
AC filter board damaged.
3-pahse bridge rectifier damaged.
Compressor Inverter module damaged.
Procedure 4.22.4
Refer to P6 protection: xL1 and Xl2.