EasyManuals Logo

Midea V4+R Series User Manual

Midea V4+R Series
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #55 background imageLoading...
Page #55 background image
V4+R VRF 50/60Hz
201608 53
Part 5 - Diagnosis and Troubleshooting
4.3 E1 Troubleshooting
Digital display output 4.3.1
Description 4.3.2
Phase sequence error.
All units stop running.
Error code is only displayed on the unit with the error.
Possible causes 4.3.3
Power supply phases not connected in correct sequence.
Power supply terminals loose.
Power supply abnormal.
Main PCB damaged.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Midea V4+R Series and is the answer not in the manual?

Midea V4+R Series Specifications

General IconGeneral
BrandMidea
ModelV4+R Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals