Water inlet fault
Problem Cause and remedy
The warning buzzer is
sounding.
One of the following
messages appears in
the display:
Open stopcock The stopcock is closed.
Open the stopcock fully.
Water intake Before rectifying the problem:
Switch the dishwasher off.
The water inlet is restricted.
Open the stopcock fully and start the programme
again.
Clean the filter in the water inlet (see “Cleaning
and care” – Cleaning the filter in the water inlet”).
The water-connection pressure is lower than
50kPa.
Seek professional advice.
The on-site connection for the water drainage may
be too low and you will need to vent the water
drainage (see “Installation – Water drainage”).
The following fault mes-
sage appears on the
display during the Sol-
arSaveprogramme:
Intake temperature too low
The intake water has not reached the required tem-
perature of 45°C (see “Installation – Water inlet”).
Start the programme again.
If the fault message appears again, select a differ-
ent programme.