Installation
47
Drainage
DN 70 drain valve AV on the machine, DN 70 sleeve on-site.
Throughflow rate 200l/min.
If the slope for drainage is extremely steep, the piping must be vented
to prevent formation of a vacuum in the machine's drain system.
Foam and vapour venting kitBWS
If excessive suds form, foam may escape from the vapour vent. To
remove the foam, an optional vapour venting kit (BWS) can be used.
Electrical connection
The electrical connection must only be carried out by a suitably
qualified electrician in accordance with local and national regulations.
Useful tip: Open the machine lid. The connection terminals are
located on the machine support.
When installing a residual current device (RCD), it must be Type B.
The electrical components of this machine comply with
DINEN60335-1, DINEN50571.
See data plate for voltage data.
If the machine is hard wired, an all-pole isolator must be installed.
Switches with a minimum contact gap greater than 3mm are suitable
isolators. These include circuit breakers, fuses, and contactors
(VDE0660).
The plug connector or isolator switch should be easily accessible at
all times.
If the appliance is disconnected from the electricity supply, the
isolator must be lockable or the point of disconnection must be
monitored at all times.
Observe the enclosed wiring diagram.