EasyManuals Logo

Miller Axcess E Dual User Manual

Miller Axcess E Dual
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #40 background imageLoading...
Page #40 background image
OM-248965 Page 36
SECTION 7 SETTING SEQUENCE PARAMETERS
7-1. Sequence Parameters In A Program
.
For more information on
Sequence mode, see Feeder
Set Up Push Button in Section
6-9.
Weld Time can only be set by using
the HTML pages.
If time is set to Off in Weld
sequence, welding continues until
gun trigger is released.
If time is set to zero in any timed
sequence except Weld, the
sequence is skipped.
. Maximum IPM may actually
be lower depending on wire
size and gas combination.
Additional sequence set up
changes can be made using the
HTML pages. Refer to the HTML
pages for additional information.
Trigger
Pressed
Trigger
Released
Time
Start
Time
Preflow
Weld
Crater
Time
Postflow
Start
Time
Time
PostflowCrater
Weld
Preflow
Sequence
End
Volts/Trim IPM Seconds
5. Postflow Off-10.0
X = Setting available.
1. Preflow Off-10.0
Sequence Parameters
2. Start
3. Crater
Off-10.0
Off-10.0
10.0-44.0/
0-99
40-1400/
0-99
10.0-44.0/
0-99
40-1400/
0-99
4. Retract Off-10.0
50-500
Retract
Time
Retract