OM-188 415 Page 8
2-6. Installing Wire Spool and Adjusting Hub Tension
ST-072573-B
When a slight force is needed to turn spool, tension is set.
15/16 in
Tools Needed:
2-7. Positioning Jumper Links
Check input voltage available at
site.
1 Jumper Links Access
Remove side panel.
2 Jumper Link Label
Check label ā only one is on unit.
3 Input Voltage Jumper Links
Move jumper links to match input
voltage.
Close and secure side panel.
230V
400V
2-8. Electrical Service Guide
183 243 323
Input Voltage
230 400 230 400 230 400
Input Amperes at Rated Output
16 9 23 13 24 41
Max Recommended Standard Fuse or Circuit
Breaker Rating in Amperes
16 9 23 13 24 41
** Input Conductor Size in mm
2
2.5 2.5 2.5 2.5 6 6
** Grounding Conductor Size in mm
2
2.5 2.5 2.5 2.5 6 6
** Power cord supplied with the unit is sized for 230V operation. Larger power cord may be required for cable lengths greater than 3 meters. C
onsult national and local regulations.