SECTION 4 – MAINTENANCE AND TROUBLESHOOTING
4-1. Routine Maintenance
Y Disconnect power before maintaining.
3 Months
Replace unreadable labels.
Repair or replace
cracked weld cable.
Clean and tighten weld terminals.
6 Months
Blow out or vacuum inside. During
heavy service clean monthly.
OR
4-2. Circuit Breaker CB1
1 Circuit Breaker CB1
If CB1 opens, wire feeding stops.
2 Drive Roll Assembly
2
1
4-3. Unit Overload
If unit is used beyond capacity (excessive wire feed, shorted output, etc.), wire feeds but is not energized. Release gun
trigger to reset this condition.