3-44
When the eco case weight is changed
When the case weight is changed by replacing the eco case, register the weight of the eco case in the fol-
lowing procedures.
1
In the local mode, press the
key.
2
Select [MACHINE SETUP] by pressing
the keys.
3
Press the key.
4
Select [600cc Cartridge] by pressing
the keys.
When the 600 cc cartridge is not set,
“ 600 cc Cartridge” will not be displayed.
It is recommended to measure the weight of the
eco case in advance and then perform the proce-
dure from the Step 5.
5
Press the key.
6
Select [Slot] by pressing the
keys.
The selected slot is highlighted.
7
Press the key.
The weight input screen is displayed.
8
Pressing the keys
input the weight of the eco case.
Press the keys to move to another digit.
Press the keys to input the weight.
FUNCT I ON
SETUP <ENT>
FUNCT I ON
MACH I NE SE TUP <ENT >
MACH I NE SE TUP
DEODOR I ZE FAN <e n t >
MACH I NE SE TUP
600cc Car t r i dge<en t>
CART . S l o t s e l e c t
1
.34. .7.
CART . S l o t s e l e c t
1.3
4
..7.
CART.Slot ..3.....
case we i gh t = 30
0
g
CART.Slot ...4....
case we i gh t = 35
5
g