EasyManua.ls Logo

MIMAKI JV33-130BS - Setting Pump Tube Washing Interval in Standby Mode

MIMAKI JV33-130BS
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-34
Setting Pump tube washing interval in Standby mode
Perform the pump tube washing periodically to prevent ink from clogging due to the coagulation of ink,
which occurs within the tube.
1
Select [ROUTINE SETUP] of the maintenance menu.
(1) Press the key in the local mode.
(2) Select [MAINTENANCE] by pressing the keys then press the key.
(3) Select [ROUTINE SETUP] by pressing the keys.
(4) Press the key.
2
Select [PUMP TUBE WASH] by press-
ing the keys.
3
Press the key.
4
Set the tube washing interval by press-
ing the keys.
Set value : OFF, 1 - 168 hours
5
Press the key.
6
Press the key several times to end.
This function is operable only under the condition that the machine is left in the following dis-
plays.
When the cleaning solution has not been filled in the
machine, the right display is displayed at the step 5. Fill the
cleaning solution ( P.4-8) then redo the operations from
the step 1.
<LOCAL .1> [#01 ] *REMOTE. 1* [#01]
0.00m
LOCAL mode REMOTE mode
ROUT I NE SETUP
PUMP TUBE WASH < en t >
ROUT I NE SETUP
WA S H I N T E R V A L =
1
h
ROUT I NE SETUP
WA S H I N T E R V A L =
4
h
ROUT I NE SETUP
PUMP TUBE WASH < en t >
** Washing Liquid **