EasyManua.ls Logo

MIMAKI UJF-6042 MkII - Warning; Error Messages

MIMAKI UJF-6042 MkII
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter6 Appendix
6-2
Specifications
Machine specifications
Item UJF-3042MkII UJF-6042MkII
Print head
Method Drop-on-demand piezoelectric print heads
Specification 3 head, 2 staggered 4 head, 2 staggered
Resolution
x-dpi: 600, 900, 1200
y-dpi: 600, 1200
Drawing
mode
600 x 600 8, 10 pass
600 x 900 12, 16 pass
1200x1200 12, 16 pass
Usable inks
Exclusive UV curing ink (Genuine ink) LH-100, LUS120, LUS150,
PR-200
Bk, C, M, Y, W, Pr(PR-200 only), CL , Lc, Lm(Lc and Lm is UJF-
6042MkII only.)
Ink supply 6 bottles 8 bottles
Usable media
Size 300 x 420mm ( 11.8 x 16.5 in ) 610 x 420mm ( 24.0 x 16.5 in )
Thickness 153mm ( 6.0 in )
Weight 5kg ( 11.0 lb ) 8kg ( 17.6 lb )
Max. printing area 300 x 420mm ( 11.8 x 16.5 in ) 610 x 420mm ( 24.0 x 16.5 in )
Distance accu-
racy
Absolute accuracy
Whichever the larger one of ± 0.3 mm(± 0.01 in) or ± 0.3 % of the
designated
Reproducibility
Whichever the larger one of ± 0.2 mm(± 0.008 in) or ± 0.1 % of the
designated
Perpendicularity ± 0.3 mm / 400mm (± 0.01 in / 15.7 in)
Print gap adjustment Table up / down mechanism by key
Head anticollision device Head anticollision by obstacle sensor
UV unit Air-cooling LED UV device x 1 (equipped with the head slider)
Waste ink tank Bottle type ( 1600 cc)
Interface
USB 2.0 (Ethernet 10 BASE/ 100 BASE/ 1000 BASE E-mail func-
tion, only “1000 BASE” connection is applicable for drawing.)
Command MRL- V
Noise
during standby Less than 55 dB (A) (FAST-A, Front & Rear & Left & Right 1 m)
during continuous printing Less than 70 dB (A)
Safety Standard
VCCI-Class A, FCC-Class A, UL 60950-1, CE Marking (EMC,Low
Voltage Directive,Machinery Directive, RoHS Directive), CB Report,
RoHS, Reach, EnergyStar, IEC60825-1
Power Single phase AC100 - 240 V ±10% 50 / 60 Hz ± 1 Hz
Power consumption 1000 W or less
Recomended
Environment
Available temp. 20 °C to 35 °C ( 68 °F to 86 °F )
Humidity 35 to 65% Rh (No condensation)
Guaranteed temp. 20 °C to 25 °C ( 68 °F to 77 °F )
Temperature change ± 10 °C / h or less ( ± 50 °F / h or less )
Dust Equivalent to normal office level
Highest operation height 2000 m ( 78.7 in )
Weight
*1
*1. Figures in the () include the dedicated stand.
135 kg (170 kg)
(297.6 lb (374.8 lb))
150 kg (185 kg)
(330.7 lb (407.9 lb))
Outside
dimensions
Width 1355 mm ( 53.3 in ) 1665 mm ( 65.6 in )
Depth 1290 mm ( 50.8 in )
Height 856 mm ( 33.7 in ) (Not including the dedicated stand and the bottle.)