Chapter 4 Maintenance
4-11
1
2
2
4
5
6
9
Fill up the cap with cleaning solution for
maintenance
Suck maintenance solution into a dropper and fill
up the cap with it. Fill up the cap with
maintenance solution on the verge of overflow
from the cap.
10
Close the maintenance cover and press
the key.
11
Press to set the time for the
cleaning solution to be left as it is.
Set Value:1 to 99 min (by the unit of 1 min)
12
Press the key.
The nozzles are washed.
When the nozzles have been completely washed,
the head moves to the maintenance position.
13
Open the maintenance cover.
14
Fill up the cap with cleaning solution for
maintenance
Suck maintenance solution into a dropper and fill
up the cap with it. Fill up the cap with
maintenance solution on the verge of overflow
from the cap.
15
Close the maintenance cover and press
the key.
After its initial operation, the machine returns to
step2.
Sub tank maintenance
Perform it if a large amount of missing nozzle is not
recovered or a nozzle missing occurs immediately after
cleaning.
1
Press the
(MENU)
in LOCAL.
2
Press to select “
MAINTENANCE
”,
and press the key.
MAINTENANCE MENU will be displayed.
3
Press to select “SUB TANK
MAINTENANCE”, and press the
key.
“SUB TANK MAINTENANCE” will be selected.
4
Press to select the head, and
press the
(
).
After selecting the head, press the [FUNC2] key
and put a check in the check box.
The head whose box has been checked will be
sub tank maintenance.
5
Press the key.
Executes "SUB TANK MAINTENANCE".