EasyManua.ls Logo

MIMAKI UJF-6042 MkII - Supplying Antifreeze Liquid

MIMAKI UJF-6042 MkII
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-20
Chapter 4 Maintenance
Supplying antifreeze liquid
If an error of lack of water occurs, supply antifreeze liquid.
1
Press the
(MENU)
in LOCAL.
2
Press to select “Maintenance”,
and press the key.
MAINTENANCE MENU will be displayed.
3
Press to select “Water FillUp”,
and press the key.
4
Press the key.
Water flow stops.
5
Open the left maintenance cover.
6
Disconnect the right end of the tube
connected to the feed-water inlet.
Indicated with "IN" label.
7
Made mixed liquid (antifreeze liquid: 1,
water: 2) in the attached reservoir and
move it to the attached syringe.
8
Refill antifreeze mixed liquid.
Fill the antifreeze mixed liquid from the feed-water
inlet.
Injection water slowly until the buzzer sounds.
9
When the buzzer sounds, stop refilling
and, press the key.
”To 200cc filling” will be displayed.
10
Supply 200cc of the liquid.
“Tie an infusion mouth” will be displayed.
11
Connect the tube to the feed-water inlet.
12
Press the key.
Pay attention while handling the tube as antifreeze
liquid flowing in it is hot.
Make sure that water flow has stopped in Step 2.
feed-water inlet
Tube
If press the [Enter] key without connecting the
tube to the feed-water inlet, the mixed liquid will be
overflowing.
WaterFillUp
To200ccfilling
[ENT]
WaterFillUp
Tieaninfusionmouth
[ENT]