4-20
Chapter 4 Maintenance
Supplying antifreeze liquid
If an error of lack of water occurs, supply antifreeze liquid.
1
Press the
(MENU)
in LOCAL.
2
Press to select “Maintenance”,
and press the key.
• MAINTENANCE MENU will be displayed.
3
Press to select “Water FillUp”,
and press the key.
4
Press the key.
• Water flow stops.
5
Open the left maintenance cover.
6
Disconnect the right end of the tube
connected to the feed-water inlet.
• Indicated with "IN" label.
7
Made mixed liquid (antifreeze liquid: 1,
water: 2) in the attached reservoir and
move it to the attached syringe.
8
Refill antifreeze mixed liquid.
• Fill the antifreeze mixed liquid from the feed-water
inlet.
• Injection water slowly until the buzzer sounds.
9
When the buzzer sounds, stop refilling
and, press the key.
• ”To 200cc filling” will be displayed.
10
Supply 200cc of the liquid.
• “Tie an infusion mouth” will be displayed.
11
Connect the tube to the feed-water inlet.
12
Press the key.
• Pay attention while handling the tube as antifreeze
liquid flowing in it is hot.
• Make sure that water flow has stopped in Step 2.
• If press the [Enter] key without connecting the
tube to the feed-water inlet, the mixed liquid will be
overflowing.
WaterFillUp
To200ccfilling
[ENT]
WaterFillUp
Tieaninfusionmouth
[ENT]