REPAIR GUIDE
Adjustment of the frequency for camera shaking (ACT DRV FREQ)
Required equipment
PC with preinstalled the 2720 adjustment program
USB-500 (USB cable)
AC-1L/AC-11
Preparation of the adjustment
1. Start up the 2720 adjustment program.
2. Connect the camera and PC with USB-500, and click "START" after confirming the USB connection.
3. Set the lens block of the camera to "Wide-angle" position.
Procedure of the adjustment
1. Click "ACT DRV FREQ" of the adjustment menu.
The adjustment is automatically started.
2. The adjustment is completed when "OK" is displayed on the adjustment menu.
Adjustment of the servo for camera shaking (SERVO GAIN)
Required equipment
PC with preinstalled the 2720 adjustment program
USB-500 (USB cable)
AC-1L/AC-11
Preparation of the adjustment
1. Start up the 2720 adjustment program.
2. Connect the camera and PC with USB-500, and click "START" after confirming the USB connection.
3. Set the lens block of the camera to "Wide-angle" position.
Procedure of the adjustment
1. Click "SERVO GAIN" of the adjustment menu.
The adjustment is automatically started.
2. The adjustment is completed when "OK" is displayed on the adjustment menu.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Minolta A2 and is the answer not in the manual?

Minolta A2 Specifications

General IconGeneral
Sensor TypeCCD
Optical Zoom7x
Display Size1.8 inches
ISO Sensitivity64 - 800
Image StabilizationNo
Max Resolution3264 x 2448
Image Ratio w:h4:3
Sensor Size2/3" (8.8 x 6.6 mm)
Maximum ApertureF2.8 - F3.5
Storage TypesCompactFlash (Type I or II), Microdrive
ViewfinderElectronic
Resolution8 megapixels
Lens Focal Length28 - 200 mm
BatteryNP-400 Lithium-Ion rechargeable battery
Shutter Speed30 - 1/4000 sec

Related product manuals