FrameMaker Ver.5.5E(PC) Di152/Di183 TROUBLESHOOTING
01.09.04
T-39
Step Check Result Action
1 Exposure Lamp turns ON when the
Power Switch is turned ON.
NO Go to step 3.
2 Exposure Lamp is abnormally lit
(flickers or abnormally dark) when
the Power Switch is turned ON.
NO Go to step 4.
3 Inverter Board (copier: PU2) connec-
tor is loose.
YES Reconnect.
NO Change Exposure Lamp (LA2).
4 CCD Board (copier: PWB-J) connec-
tor is loose.
YES Reconnect.
5 The following voltage is supplied from
the Control Board (copier: PWB-C).
<Check Procedure>
Check voltage across a Control
Board (copier: PWB-C) pin and GND
when the Power Switch is turned ON.
Voltage across JP16C-4 and GND
DC24 V when Exposure Lamp
(LA2) is OFF
DC0 V when Exposure Lamp (LA2)
is ON
YES Change Inverter Board (PU2).
NO Change Control Board (copier:
PWB-C).