FrameMaker Ver.5.5E(PC) DIS/REASSEMBLY, ADJUSTMENT FOR Di152/Di183
01.09.03
D-52
4-3. ACCESSING THE FUNCTION, TECH. REP. CHOICE, AND
ADJUST MODE
(1) Function Mode
1. Press the Meter Count key.
2. Press the following keys in this order: Stop
0
0
Stop
0
1.
3. Enter the code number “1” from the 10-Key Pad.
4. Press the Start key.
(2) Tech. Rep. Choice Mode
1. Press the Meter Count key.
2. Press the following keys in this order: Stop
0
0
Stop
0
1.
3. Enter the code number “2” from the 10-Key Pad.
4. Press the Start key.
(3) Adjust Mode
1. Press the Meter Count key.
2. Press the following keys in this order: Stop
0
0
Stop
0
1.
3. Press the Stop key and then the Start key.