(4) Cleaning of the CCD Sensor
1. Remove the Original Glass.
2. Remove 15 screws and the CCD Unit cover.
(5) Cleaning of the Scanner Rails/Bushings
3. Using a soft cloth dampened with alcohol, wipe
the Lens clean of dirt.
3. Remove the Lens cover.
4. Using a soft cloth dampened with alcohol, wipe
the CCD Sensor clean of dirt.
1. Remove the Original Glass.
2. Using a soft cloth dampened with alcohol, wipe
the Scanner rails/bushings clean of dirt.
NOTE
After the Scanner rails/bushings have been
cleaned, apply oil (copier lubricant A or FLOIL
947P).