FrameMaker Ver.5.5E(PC) Di152/Di183 TROUBLESHOOTING
01.09.04
T-49
(4) Foggy background or rough image
Section Step Check Result Action
Output
system
1 Image condition changes after “ID
Adjustment” and “VG Adjustment” have
been made.
YES Readjust.
For more details, see
SWITCHES ON PWBs/
TECH. REP. SET-
TINGS.
2 PC Drum surface and the areas in con-
tact with Ds Collars are dirty with foreign
matter, or deformed or worn.
YES Clean or change.
3 Main Erase (LA1) is dirty. YES Clean.
4 Grid bias contact is dirty, scratchy,
deformed, worn, or damaged.
YES Clean, correct, or
change.
5 ATDC Sensor (UN1) is dirty with foreign
matter (such as paper dust) other than
developer.
YES Clean.
6 The following voltages develop from the
ATDC Sensor (UN1).
<Check Procedure>
Check voltage across a Master Board
pin and GND when the Power Switch is
turned ON.
DC5.39 V to 8.15 V across PJ7A-8
and GND
DC1.41 V to 4.98 V across PJ7A-10
and GND
NO Change ATDC Sensor
(UN1) and then change
developer.
7 The following voltage is supplied from
the Master Board (copier: PWB-A).
<Check Procedure>
Check voltage across a Master Board
pin and GND when the Start key is
pressed.
Voltage across PJ8A-8 and GND
DC14 V in standby state
DC0 V when Start key is pressed
YES Adjust Db.
For details, see DIS/
REASSEMBLY,
ADJUSTMENT.
Change Main Erase
(LA1).
Change PC Drum.
Change IU.
Change High Voltage
Unit (HV1).
NO Change Master Board
(copier: PWB-A).
Input
system
1 Original Glass is dirty. YES Clean.
2 Scanner mirrors are dirty. YES Clean.
3 Exposure Lamp (LA2) is dirty. YES Clean.
4 CCD Unit lens and CCD surface are
dirty.
<Check Procedure>
Remove lens cover to check for possible
contamination.
YES Clean.