FrameMaker Ver.5.5E(PC) DIS/REASSEMBLY, ADJUSTMENT FOR Di152/Di183
01.09.03
D-62
(10) Manual Bypass Registration Adjustment
Requirement
NOTES
This adjustment is made when the PH Unit has been replaced and after “Printer Regis-
tration Adjustments (CD and FD)” and “Scanner Zoom Adjustment (CD).
This adjustment is made when the CCD Unit has been replaced and after “CCD Unit
Position Adjustment.”
Load the 1st Tray with A4C paper.
<Adjustment Procedure>
1. Enter the Adjust mode.
2. With AJ- shown on the Display, enter the code number 12 from the 10-Key Pad.
3. Press the Paper key to select the 1st Tray.
4. Press the Start key.
Then, a test print will be produced.
5. Place the test print produced on the Original Glass and make a copy using the Manual
Bypass Tray.
6. Align the test print (original) with the copy and check for deviation.
If the deviation between width A on the test print and that on the copy falls outside the
specified range, adjust the position of the Guide Plate Unit.
Adjust so that the deviation between width A on the
test print and that on the copy falls within the spec-
ified range.
Specifications: 0 ± 2.0 mm
A
4686D504AA
Adjustment Instructions
If with A of the copy is longer than that on the test
print, move the Guide Plate Unit to the rear.
If with A of the copy is shorter than that on the test
print, move the Guide Plate Unit to the front.
4022D033AA