EasyManua.ls Logo

Minolta EP5000 - Page 347

Minolta EP5000
392 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Interleaf EP5000/EP4000 TROUBLESHOOTING
97.04.01
T-72
uC0500, C0510
Step Check Item Result Action
1
Does H1 light up when the Power
Switch is turned ON?
NO
Go to step 5.
2 Is TH1 installed properly? NO Reinstall TH1.
3 Is TH1 dirty? YES Clean or change TH1.
Measure resistance of TH1. Is is infi- YES Change TH1.
4
nite?
NO Change PWB-A.
5
Perform the Controller Board Check.
Is malfunction code “C0311” displayed?
YES
Change PWB-A.
Check H1 for continuity. Is there conti- YES Change SSR1.
6
nuity?
NO
Change H1 or TS1.
uC0520
Step Check Item Result Action
1
Does H1 remain lit after the copier has
warmed up?
NO
Go to step 4.
2
Perform the Controller Board Check.
Is malfunction code “C0311” displayed?
YES
Change PWB-A.
3 Does H1 turn OFF? NO Change SSR1.
4 Is TH1 installed properly? NO Reinstall TH1.
5 Is TH1 dirty? YES Clean or change TH1.
Measure resistance of TH1. Is is 0 YES Change TH1 (TH2).
6
or close to 0?
NO Change PWB-A.