46 TX3 Telephone Access System Programming Manual Version 2.7
LT-979 Copyright 2018
Configuration
To define inputs
1. Press the arrow key to scroll to Inputs, and press the enter (telephone) key.
The “Input Types” selection appears.
2. Press the arrow key to scroll to the input you wish to configure and press
the telephone (enter) key. The Input Active State selection appears.
3. Use the “#” key to define the input state as open or closed.
4. Press the telephone (enter) key to accept. The circuit supervision selection
appears.
5. Press the arrow key to scroll to the input you wish to configure and use the
“#” key to define the input state as No supervision, Open, Short or Open &
Short
6. Press the telephone (enter) key. The “Input Types” selection appears.
7. Proceed with the rest of the input configuration or
8. Press info key to return to previous menu.
Input Types
1 Postal lock
2 Fire P Override
3 Door Sense
4 GP Input 3
5 GP Input 4
Ipt Active State
[ ] Close
Supervised for-
[ x ] No supervision
[ ] Open
[ ] Short
[ ] Open & Short