Instruction Manual MIT-SCAN-T3 Version 02/2021
Page 38
Sel. Reflector(selected reflector):
Display of set up reflector
Rating”: The calculated reflector format provides a check of the
conformity between measured reflector and set antipole.
Condition”: With the calculated coefficient, it is possible to
assess whether a reflector is damaged (but still measurable) or
destroyed (not measurable).
3.4 Functionality check acc. to TP D-StB 12
Before starting the days first measurement, the thickness measuring
devices functionality must be tested.
5
The German standard TP D-StB 12 requires that the first measurement
has to be a check of the correct device function. For this, with the
device traverse the measuring site and perform a measurement. Use
the MIT wheeled spacer (s. Fig. 33) and fix it to the probe. Repeat the
measurement with a mobile spacer. The MIT wheeled spacer increases
the distance between probe and road surface by 35 mm.
5
Source: TP D-StB 12, sec. 2.2.6
Functionality check:
1. Perform measurement
2. Fit MIT wheeled spacer to
device
3. Remeasure measuring site
4. Subtract the defined
amount of 35 mm from
second measurement
result
5. First and second
measurement end values
should not differ by more
than 1 mm.
Fig. 33 MIT wheeled spacer