8 PARAMETER SETTINGS
8.2 Settings for the Master Station in MELSEC-Q/L
Displayed items
*1 Extended data register (D) and extended link register (W) are also included.
Item Description Setting range Default
Use the CC-Link IEF Basic Set whether to use CC-Link IE Field Network Basic. Checked
Unchecked
Unchecked
Network
Configuration
Settings
[Network Configuration
Settings] button
Set the information of the slave station to the master
station. Setting items are the same as GX Works3. (
Page 35 Network Configuration Settings)

Refresh
Settings
Link Side The number of points for the link devices (RX/RY, RWr/
RWw) for the number of occupied stations and start/end
device number set in the network configuration settings are
displayed.

CPU Side Device
Name
Set the device of the link refresh target. X, Y, M, L, B, D
*1
, W
*1
, R, ZR (Empty)
Points The number of device points for the link refresh target is
displayed. (The same value as the number of points on the
link side is displayed.)

Start Set the start device number within the link refresh range. Follow the device settings of the
CPU parameters.
(Empty)
End The end device number within the link refresh range is
displayed.
