4 SAFETY MONITORING FUNCTIONS
Safety Communication Function 4-77
4.7.4 Transmission delay time
The transmission delay time of the safety communication function is calculated as follows.
(1) The time from when the safety device of the safety CPU module (sending station) turns OFF until when the
SCNI signal of the robot controller (receiving station) turns OFF and the safety monitoring function is
enabled
(2) The time from when the safety monitoring function of the robot controller (sending station) is enabled and
the SCNO signal turns OFF until when the safety device of the safety CPU module (receiving station) turns
OFF
Calculation value
Formula
Normal value
SCsnd + LS + SCrcv + TMsnd + (SCrc × 1.5)
Maximum value
SCsnd + (LS × 2) + (SCrcv × 2) + TMsnd + (SCrc × 1.5)
SCsnd: Safety cycle time (sending station)
SCrcv: Safety cycle time (receiving station)
SCrc: Safety cycle time (robot controller: 7.11[ms])
LS: Communication cycle interval (cyclic data transfer processing time)
TMsnd: Transmission interval monitoring time (sending station)
The safety cycle time of the robot controller is 7.11 [ms].
The safety cycle time of the safety CPU module and CC-Link IE TSN communication cycle interval (LS) are the
parameter values set in the safety CPU module and master/local module. Refer to the following manuals.
□ MELSEC iQ-R CPU Module User's Manual (Startup) (SH-081263ENG)
□ MELSEC iQ-R CPU Module User's Manual (Application) (SH-081264ENG)
□ MELSEC iQ-R CC-Link IE TSN User's Manual (Startup) (SH-082127ENG)
□ MELSEC iQ-R CC-Link IE TSN User's Manual (Application) (SH-082129ENG)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric CR800-R and is the answer not in the manual?

Mitsubishi Electric CR800-R Specifications

General IconGeneral
Maximum Axes8
Protection ClassIP20
Compatible RobotsMELFA Robots
Communication InterfaceEthernet
Programming LanguageMELFA-BASIC V
Operating Temperature0 to 50°C
Storage Temperature-20°C to 60°C

Related product manuals