336
APPX
Appendix 6 Dedicated Instruction
CC-Link dedicated instructions
The following table lists the instructions used for transient transmission with CC-Link IE Field Network-compliant devices.
*1 The instruction cannot be executed to an intelligent device station from a local station. Execute it on the master station.
Transient transmission range of CC-Link dedicated instructions
Communication with all stations in the same network is possible.
Communication is not available with stations in other networks.
SLMP communication instruction
The following table lists the dedicated instruction used to send an SLMP frame to an SLMP-compatible device in the same
network.
Other dedicated instructions
The following table lists the dedicated instructions used to set parameters for the master/local module of the own station.
Transient transmission range of other dedicated instructions
Only the master/local module of the own station can be accessed.
Instruction Description
RIRD
*1
Reads the specified points of data from the target station device.
RIWT
*1
Writes the specified points of data to the target station device.
Instruction Description
SLMPREQ Reads, writes, and operates data of the target station.
Instruction Description
CCPASET Sets parameters for the master/local module.
UINI Sets a station number for a local station.