4. STARTUP 
4 -  29 
 
(2) Operation example 
(a)  Parameters of 5 or less digits 
The following example shows the operation procedure performed after power-on to change the 
control mode to the speed control mode with [Pr. PA01 Operation mode]. Press "MODE" to switch to 
the basic setting parameter screen. 
ࡄࡔ࠲⇟ภࠍ␜ߒ߹ߔޕ
"UP"ࡏ࠲ࡦ߹ߚߪ"DOWN"ࡏ࠲ࡦࠍߔߣ⇟ภ߇ᄌࠊࠅ߹ߔޕ
ᜰቯߒߚࡄࡔ࠲ߩ⸳ቯ୯߇ὐṌߒ߹ߔޕ
"SET"ࡏ࠲ࡦࠍ2࿁ߒ߹ߔޕ
"SET"ࡏ࠲ࡦࠍߒߡ⏕ቯߒ߹ߔޕ
"UP"ࡏ࠲ࡦࠍ2࿁ߒ߹ߔޕ
ὐṌߪ⸳ቯ୯ࠍᄌᦝߢ߈߹ߔޕ
"UP"ࡏ࠲ࡦ߹ߚߪ"DOWN"ࡏ࠲ࡦࠍ↪ߒߡߊߛߐޕ
(_ _ _ 2: ㅦᐲᓮࡕ࠼)
 
To shift to the next parameter, press the "UP" or "DOWN" button. 
When changing the [Pr. PA01] setting, change its set value, then switch power off once and switch it 
on again to make the new value valid. 
 
The parameter number is displayed. 
Press "UP" or "DOWN" to change the number.
Press "SET" twice.
The set value of the specified parameter number flickers.
Press "SET" twice.
During flickering, the set value can be changed. 
Use "UP" or "DOWN". 
(_ _ _ 2: Speed control mode)
Press "SET" to enter.