5. PARAMETERS
5 - 44
5.2.6 Extension setting 3 parameters ([Pr. PF_ _ ])
Control
mode
No./symbol/name
Setting
digit
Function
Initial
value
[unit]
PST
PF21
DRT
Drive recorder
switching time
setting
This is used to set a drive recorder switching time.
When a USB communication is cut during using a graph function, the function will
be changed to the drive recorder function after the setting time of this parameter.
When a value from "1" to "32767" is set, it will switch after the setting value.
However, when "0" is set, it will switch after 600 seconds.
When "-1" is set, the drive recorder function is disabled.
Setting range: -1 to 32767
0
[s]
PF23
OSCL1
Vibration tough
drive -
Oscillation
detection level
This is used to set a filter readjustment sensitivity of [Pr. PB13 Machine
resonance suppression filter 1] and [Pr. PB15 Machine resonance suppression
filter 2] while the vibration tough drive is enabled.
Example: When you set "50" to the parameter, the filter will be readjusted at the
time of 50% or more oscillation level.
Setting range: 0 to 100
50
[%]
PF24
OSCL2
Vibration tough
drive function
selection
_ _ _ x Oscillation detection alarm selection
Select alarm or warning when a oscillation continues at a filter readjustment
sensitivity level of [Pr. PF23].
The digit is continuously enabled regardless of the vibration tough drive in [Pr.
PA20].
0: [AL. 54 Oscillation detection] will occur at oscillation detection.
1: [AL. F3.1 Oscillation detection warning] will occur at oscillation detection.
2: Oscillation detection function disabled
0h
_ _ x _ For manufacturer setting 0h
_ x _ _ 0h
x _ _ _ 0h
PF25
CVAT
Instantaneous
power failure
tough drive -
Detection time
Set the time of the [AL. 10.1 Voltage drop in the control power] occurrence.
To disable the parameter, select "Disabled (_ 0 _ _)" of "Instantaneous power
failure tough drive selection" in [Pr. PA20].
Setting range: 30 to 200
200
[ms]
PF31
FRIC
Machine
diagnosis
function -
Friction
judgement
speed
Set a motor speed to divide a friction estimation area into high and low for the
friction estimation process of the machine diagnosis.
However, setting "0" will be the value half of the rated speed.
When your operation pattern is under rated speed, we recommend that you set
half value to the maximum speed with this.
ォᤨᦨ
[Pr.PF31]⸳ቯ
ォࡄ࠲࡯ࡦ
0r/min
ࠨ࡯ࡏࡕ
࿁ォㅦᐲ
ᱜォᣇะ
ㅒォᣇะ
Setting range: 0 to permissible speed
0
[r/min]
Maximum speed in operation
[Pr. PF31] setting
Operation pattern
0 r/min
Forward
rotation
direction
Servo motor
speed
Reverse
rotation
direction