7. SPECIAL ADJUSTMENT FUNCTIONS 
7 -  26 
 
(2)  Instantaneous power failure time of the control circuit power supply < [Pr. PF25 Instantaneous power 
failure tough drive - Detection time] 
Operation status differs depending on how bus voltage decrease. 
 
(a)  When the bus voltage decrease lower than 158 V DC within the instantaneous power failure time of 
the control circuit power supply 
[AL. 10 Undervoltage] occurs when the bus voltage decrease lower than 158 V DC regardless of the 
enabled instantaneous power failure tough drive. 
ᓮ࿁〝㔚Ḯ
Უ✢㔚
⿷㔚ࡌ࡞
(DC158V)
CALM
(ㅢ㓚)
[Pr.PF25]
ᓮ࿁〝㔚Ḯ⍍ᤨ㑆
MTTR
(࠲ࡈ࠼ࠗࡉ)
MBR
(㔚⏛ࡉࠠ
ࠗࡦ࠲ࡠ࠶ࠢ)
ࡌࠬ࿁〝
ON
OFF
ON
OFF
ON
OFF
WNG
(⼊๔)
ON
OFF
ON
OFF
ON
OFF
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Instantaneous power failure time of the control 
circuit power supply
Control circuit power 
supply
Bus voltage
Undervoltage level 
(158 V DC)
WNG 
(Warning)
MTTR 
(During tough drive)
MBR 
(Electromagnetic 
brake interlock)
Base circuit
LM 
(Malfunction)