3. SIGNALS AND WIRING 
3 -  4 
 
(2) For 1-phase 200 V AC to 240 V AC power supply of MR-J4-10A to MR-J4-70A 
 
POINT 
 
Connect the 1-phase 200 V AC to 240 V AC power supply to L1 and L3. One of 
the connecting destinations is different from MR-J3 Series Servo Amplifier. 
When using MR-J4 as a replacement for MR-J3, be careful not to connect the 
power to L2. 
 
 
MC(ᵈ6)
ALM
DICOM
DOCOM
CN3
DC24V
RA1
L1
L2
L3
න⋧
C200V㨪240V
ࠨࡏࠕࡦࡊ
P3
P4
P+
L11
L21
N-
D
C
U
V
W
(ᵈ1)
(ᵈ2)
CNP1
CNP3
PE
CNP2
ࠨࡏࡕ࠲
U
V
W
M
ࡕ࠲
ࠛࡦࠦ࠳
CN2
㓚
RA1
ࠝࡈ
MC
ࠝࡦ
MC
SK
㕖Ᏹᱛࠬࠗ࠶࠴
CN8
MCCB
(ᵈ3)
ࠛࡦࠦ࠳
ࠤࡉ࡞
(ᵈ5)
(ᵈ8)
⍴⛊ࠦࡀࠢ࠲
(ࠨࡏࠕࡦࡊߦઃዻ)
(ᵈ9)
(ᵈ4)
㓚
CN1
ᒝᱛ2
ࠨࡏࠝࡦ
(ᵈ4)
EM2
SON
DOCOM
(ᵈ7)
࿁〝㔚Ḯ
 
Note   1. 
 
 2. 
 
 3. 
 
 4. 
 5. 
 6. 
 
 
 
 7. 
 
 8. 
 9. 
Always connect between P3 and P4 terminals. (factory-wired) When using the power factor improving DC reactor, 
refer to section 11.11. Use either the power factor improving DC reactor or the power factor improving AC reactor. 
Always connect between P+ and D terminals. (factory-wired) When using the regenerative option, refer to section 
11.2. 
For the encoder cable, use of the option cable is recommended. For selecting cables, refer to Servo Motor Instruction 
Manual (Vol. 3). 
This diagram is for sink I/O interface. For source I/O interface, refer to section 3.9.3. 
For connecting servo motor power wires, refer to Servo Motor Instruction Manual (Vol. 3). 
Use a magnetic contactor with an operation delay time (interval between current being applied to the coil until closure 
of contacts) of 80 ms or less. Depending on the main circuit voltage and operation pattern, bus voltage decreases, 
and that may cause the forced stop deceleration to shift to the dynamic brake deceleration. When dynamic brake 
deceleration is not required, slow the time to turn off the magnetic contactor. 
Configure up a circuit to turn off EM2 when the main circuit power is turned off to prevent an unexpected restart of the 
servo amplifier. 
When not using the STO function, attach a short-circuit connector supplied with a servo amplifier. 
When wires used for L11 and L21 are thinner than wires used for L1, and L3, use a molded case circuit breaker. 
(Refer to section 11.10.) 
 
Malfunction
 Off
 On
EMG stop switch
Servo amplifier
Servo motor
1-phase  
200 V AC to 240V AC
MC (Note 6)
(Note 9)
(Note 1)
(Note 2)
(Note 5)
Motor
  Encoder
    (Note 3) 
Encoder cable
(Note 4)
Malfunction
24 V DC
Forced sto
 2
Servo-on
(Note 4)
(Note 8) 
Short-circuit connector 
(Packed with the servo amplifier)
(Note 7) 
Main circuit  
power supply