3. SIGNALS AND WIRING 
3 -  36 
 
(b)  SP1 (Speed selection 1), SP2 (Speed selection 2), and speed command value 
Select any of the speed settings by the internal speed commands 1 to 3 and by VC (Analog speed 
command) using SP1 (Speed selection 1) and SP2 (Speed selection 2) as follows. 
 
(Note) Input device
SP2 SP1 
Speed command value 
0  0  VC (Analog speed command) 
0  1  Pr. PC05 Internal speed command 1 
1  0  Pr. PC06 Internal speed command 2 
1  1  Pr. PC07 Internal speed command 3 
 
Note. 0: Off 
1: On 
 
To select VC (Analog speed command) and a speed command value of internal speed commands 1 
to 7, enable SP3 (Speed selection 3) with [Pr. PD03] to [Pr. PD22]. 
 
(Note) Input device 
SP3 SP2 SP1 
Speed command value 
0  0  0  VC (Analog speed command) 
0  0  1  Pr. PC05 Internal speed command 1 
0  1  0  Pr. PC06 Internal speed command 2 
0  1  1  Pr. PC07 Internal speed command 3 
1  0  0  Pr. PC08 Internal speed command 4 
1  0  1  Pr. PC09 Internal speed command 5 
1  1  0  Pr. PC10 Internal speed command 6 
1  1  1  Pr. PC11 Internal speed command 7 
 
Note. 0: Off 
1: On 
 
You can change the speed during rotation. To accelerate/decelerate, set acceleration/deceleration 
time constant in [Pr. PC01] or [Pr. PC02]. 
When the internal speed commands are used to command a speed, the speed does not vary with 
the ambient temperature. 
 
(2)  SA (Speed reached) 
SA turns on when the servo motor speed has nearly reached the speed set to the internal speed 
command or analog speed command. 
ౝㇱㅦᐲᜰ1
ౝㇱㅦᐲᜰ2
⸳ቯㅦᐲㆬᛯ
ST1߹ߚߪST2
ON
OFF
ࠨࡏࡕ࠲
࿁ォㅦᐲ
SA(ㅦᐲ㆐)
ON
OFF
 
(3) Torque limit 
As in section 3.6.1 (5) 
 
Internal speed 
command 1
Internal speed 
command 2
Set speed selection
ST1 or ST2
Servo motor speed
SA (Speed reached)