7 - 141
7 MOTION PROGRAMS FOR POSITIONING CONTROL
7.16.8 32-bit real number and 64-bit real number data conversion (DFLT, SFLT)
Code DFLT, SFLT
Function
32-bit real number and 64-bit
real number data conversion
The DFLT instruction converts the data from 32-bit real number to 64-
bit real number.
The SFLT instruction converts the data from 64-bit real number to 32-bit
real number.
Format
L
Indirect setting only
F[]nT
32bit real number 64bit real number data
conversion command
;D
L
Indirect setting only
F[]nT ;S
64bit real number 32bit real number data
conversion command
[Explanation]
(1) DFLT : 32-bit real number data (a floating-point type) is converted 64-bit real
number data (a floating-point type).
(2) SFLT : 64-bit real number data (a floating-point type) is converted 32-bit real
number data (a floating-point type).
[Program Example]
#2004F = DFLT [#2002L] ;
#2010L = SFLT [#2012F] ;
REMARK
32-bit real number data is used in QCPU, and the data conversion between Motion
CPU and PLC CPU must use this instruction.
[64-bit double precision real number type]
Bits 0 to 51 : Significant digit part (virtual part)
63 51 Bit 0
Bit 63 : Sign part
Bits 52 to 62 : Exponent part
[32-bit double precision real number type]
Bits 0 to 22 : Significant digit part (virtual part)
31 23 Bit 0
Bits 31 : Sign part
Bits 23 to 30 : Exponent part