EasyManua.ls Logo

Mitsubishi Electric Q172CPUN - G25 High-Speed Oscillation

Mitsubishi Electric Q172CPUN
634 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 - 83
7 MOTION PROGRAMS FOR POSITIONING CONTROL
7.13.15 G25 High-speed oscillation
Code G25
Function High-speed oscillation
The specified axis oscillates in a Sine curve.
Format
2
Frequency
(Indirect setting is possible)
5XSATsSRKaFf;
G
TR T
Frequency designation
(Indirect setting is possible)
Amplitude designation
Amplitude (Indirect setting is possible)
Starting angle (Indirect setting is possible)
Starting angle designation
Axis name
[Explanation]
(1) The specified axis oscillates in a Sine curve.
0
Amplitude
360[degree]
Starting angle
Amplitude : The oscillating amplitude is specified in the setting unit. It can be
specified indirectly with a variable, D, W, or # (2-word data). The
setting range is 1 to 2147483647. If the setting is outside the range, a
minor error will (error code : 585) occur and it cannot be started.
Starting angle : The start position with the angular position of a Sine curve is
specified. It can be specified indirectly with a variable, D, W, or # (2-
word data). Set it within the range of 0 to 359.9[degree] in 0.1[degree]
increments. If the setting is outside the range, a minor error will (error
code : 586) occur and it cannot be started.
Frequency : The number of cycles in which the axis will be operated for 1 minute
in a Sine curve is specified. It can be specified indirectly with a
variable, D, W, or # (2-word data). The setting range is 1 to
5000[CPM]. If the setting is outside the range, a minor error will (error
code : 587) occur and it cannot be started.
(2) This command is valid for the specified block only (modal group (00)).
(3) After a start, operation continues until G26 high-speed oscillation stop is executed
or the stop command is input.
(4) Acceleration/deceleration processing is not performed. When not making it start
rapidly, set the starting angle to 90.0[degree] or 270.0[degree].

Table of Contents

Other manuals for Mitsubishi Electric Q172CPUN

Related product manuals