491
APPENDICES
A
Appendix 2 List of Special Relay Areas
(16)Redundant system (other system CPU information
*1
)
The special relay (SM1600 to SM1649) is valid when the redundant system is in backup mode and is invalid in
separate mode. All bits are set to off for stand-alone systems.
*1 Diagnostic information of the CPU module in the other system is stored.
*2 Special relay areas (SM) for the CPU module in the host system
Number Name Meaning Explanation
Set by
(When Set)
Corresponding
Host
SM
*2
Corresponding
CPU
SM1600
Other system
error flag
OFF: No error
ON: Error
This relay turns on if an error is detected
by error check for redundant system. (This
relay turns on when any of the SD1600 bits
turns on.)
This relay turns off when an error is
cleared.
S (Every
END
processing)
QnPRH
SM1610
Other system
diagnostics error
OFF: No error
ON: Error
This relay turns on if a diagnostic error
occurs in the CPU module in the other
system. (Also turns off when an
annunciator turns on and when an error is
detected by the CHK instruction.)
The SM0 status for the CPU module in the
other system is reflected.
S (Every
END
processing)
SM0 QnPRH
SM1611
Other systems
self diagnostics
error.
OFF: No error
ON: Error
This relay turns on if a self-diagnostics
error occurred in the CPU module in the
other system. (Excluding error detection by
an annunciator and the CHK instruction.)
The SM1 status for the CPU module in the
other system is reflected.
S (Every
END
processing)
SM1 QnPRH
SM1615
Other system
common error
information
OFF: No common error
information
present
ON: Common error
information
present
This relay turns on when there is error
common information data for an error
occurred in the CPU module in the other
system.
The SM5 status for the CPU module in the
other system is reflected.
S (Every
END
processing)
SM5 QnPRH
SM1626
Error individual
information for
other systems
OFF: No individual
error information
present
ON: Individual error
information
present
This relay turns on when there is error
individual information for an error occurred
in the CPU module in the other system.
The SM16 status for the CPU module in
the other system is reflected.
S (Every
END
processing)
SM16 QnPRH
SM1649
Standby system
cancel error flag
OFF ON:Cancels
error of standby
system
This relay is turned on from off to clear a
continuation error occurred in the standby
system. Use SD1649 to specify the error
code of the error to be canceled.
U QnPRH