1-1
Error no. H0001
1Error list
1 Error list
(1) Error No.
When an error occurs, a 5-digit error No. (example: "C0010") will appear at the STATUS NUMBER display on the
operation panel at the front of the controller, and the [RESET] switch lamp will light.
The four-digit error number (number except the one character of the head.) is displayed on LCD of T/B.
Example: In the case of C0010, display the display and the error message for "0010."
The message, cause and measures to be taken are displayed in Table 1-1 for the error Nos. that may appear.
Also, a detailed message will be displayed on the Error History screen of the T/B, depending on the error No. of
the error occurred. Check by displaying the Error History screen after resetting the error.
If the error recurs even after the measures in the table are taken, contact your service provider.
(2) If the display of the operation panel goes out
If the operation panel display of the front of the controller (drive unit) goes out, turn off the power supply once,
and turn on again.
If the error occurs, please take measures with reference to "Table 1-1: Error list" And, please confirm the error
history, even if no error occurred, and take necessary measures. Refer to the separate manual, "Instruction
Manual/Detailed Explanation of Functions and Operations" for the confirmation method of the error history. If
the operation panel display goes out again after measures, please contact to your service provider.
(3) Cause and measures against the error
The details, cause and measures of the error number occurrence are shown in Table 1-1.
Note) The contents of the error caused with option products are written in the instruction manual of the option.
Refer to each instruction manual.
Table 1-1 : Error list
Error No. Error cause and measures
H0001 Error message Fail safe error (SRVOFF)
Cause The system may be abnormal.
Measures Turn the power OFF and ON once. If it comes back, contact to your service provider.
H0002 Error message Fail safe error (STOP)
Cause The system may be abnormal.
Measures Turn the power OFF and ON once. If it comes back, contact to your service provider.
H0003 Error message The system is abnormal.
Cause The problem of the system is the cause.
Measures If it comes back, contact to your service provider.
H0004 * Error message CPU Watch dog error
Cause CPU was not normally treatable
Measures It is necessary to change some parts when not improvement. If it comes back, contact to your service
provider.
[Note] ・ The meaning of the error Nos. in Table 1-1 are shown below.
□ 0000
*
・An error marked with a * reset by turning the power OFF and ON.
Take the measures given.
・ The error type is indicated with a 4-digit number.
・ Three types of error classes are indicated.
H: High level error.................The servo turns OFF.
L: Low level error ..................The operation will stop.
C: Warning ................................The operation will continue.
・ The axis No. may be indicated at the last digit of the error No.
Example) H0931 No. 1 axis motor overcurrent.