OPERATION/CONTROL
50
3.2.5 Parameter setting method
•
 
A parameter value may either be set by updating its parameter number or setting the value digit-by-digit
using the 
 key.
•
 
To write the setting, change it and press the 
SET
 key 1.5 seconds.
Example: To change the Pr. 79 "operation mode selection" setting from "2" (external operation mode) to "1"
(PU operation mode)
(For details of Pr. 79, refer to page 105.)
STOP
RESET
MODE
SET
SET
SET
SET
SET
SET
SET
When    appears
1) When the [FWD] or [REV] indication is lit, 
    stop operation by pressing the            key 
    or turning off the forward rotation (STF) 
    or reverse rotation (STR) signal connected 
    to the control terminal.
2) You cannot set any value that is outside the 
    parameter setting range. Write a value within
    the setting range.
"
Current setting
"
Setting change
Press for
1.5 s 
Middle digit flickers
Most significant
digit flickers
Least significant
digit flickers
0 to 9
"
Setting write
Flicker
To 3.2.6 Operation mode
0 to 9
×
7 times
  or
×
3 times
×
9 times
  or
×
1 times
"1" (PU operation mode) has been set in Pr. 79.
If the value and         do not flicker but 
     appears, you did not press the        key
 for 1.5 seconds when writing the value.
Press the     key once, press the        key, and 
restart the setting from the beginning.
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
MON EXT PU
REV FWD
"
Parameter setting mode
Press the      key, to choose the 
parameter setting mode.
MODE
3