OPERATION/CONTROL
56
3.3.3 PU operation mode
(Operation using the operation panel (FR-DU04))
(
1
)
 Operation at 60Hz
While the motor is running, repeat the following steps 2 and 3 to vary the speed:
Step Description Image
1
Power-on 
→
 Operation mode check
Switch power on and make sure that the operation command
indication "PU" is lit.
(If it is not lit, press the 
MODE
 key to choose the operation mode and
press the 
 key to switch to PU operation.)
ON
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
2
Running frequency setting
Set the running frequency to 60Hz.
First, press the 
MODE
 key to select the frequency setting mode. Then,
press the 
 key to change the setting, and press the 
SET
 key
to write the frequency.
(or)
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
3
Start
Press the 
FWD
 or 
REV
 key.
The motor starts running. The monitoring mode is automatically
selected and the output frequency is displayed.
REV
FWD
(or)
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
4
Stop
Press the 
STOP
RESET
 key.
The motor is decelerated to a stop.
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
(
2
)
 PU jog operation
Hold down the 
FWD
 or 
REV
 key to perform operation, and release it to stop.
1) Set Pr. 15 "jog frequency" and Pr. 16 "jog acceleration/deceleration".
2) Select the PU jog operation. (Press the 
MODE
 key to choose the operation mode and press the 
 key
to switch to PU JOG operation.)
3) Hold down the 
FWD
 or 
REV
 key to perform operation.
(If the motor remains stopped, check Pr. 13 "starting frequency". The motor will not start if its setting is
lower than the starting frequency.)
3